Heavy Duty Heater Guards
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CLEARANCES
The following minimum clearances should be added to the overall dimensions of each wall mounted heater guard.

Height
100mm minimum above the top of the heater and 80mm below.

Depth
80mm from the front face of the heater.

Length
150mm to the overall length of the heater for the internal brackets.


Note that the length assumes the fused switch serving the heater is sited external to the guard. If the isolator is internal, then the guard will need to be longer.

ACCESS PANELS
Hinged, lockable, access panels are provided as and when required, in the most suitable position for controls access. This is normally in the front or side of the guard. Access in the top face is unsuitable as this blocks the grillage and leads to the access panel becoming hot.